Contact Us

MODEL NO: TZ 50AW Download Brochures


TZ 2
Feed Gas preparation
Feed Gas Inbuilt Oxygen concentrator
Outlet Pressure 9 psi (0.65 bar)
Compressor Air flow oil less
Oxygen Purity 93% ± 3%
Oxygen flow control 1 to 10 LPM
Sound Level < 45 dB (A)
Power supply AC 230V+ 10%, 50 Hz + 10%
Electrical classification II class B type
Temperature range 10° C – 40° C
Relative Humidity 20% to 70%
Ozone Generation
Ozone generation 50 grams per hour
Ozone concentration 100 gm / CUM
Make & Type of Electrode Technozone make / Alumina coated ceramic tube electrode with high concentration of ozone
Cooling tube arrangement / material of tube Water cooled SS 316 inner & 304 outer cooling water jacket tube. Flange ended with Teflon (zero leak proof). Can withstand pressure up to 4 bar
Ozone Generation by Corona discharge technology Advanced Ceramic coated & glazed electrode covered with concentric annular SS cooling tube is alternated with high frequency corona discharge. This corona dischargedisassociates the oxygen atoms to regroup toform ozone
Power electronics Full bridge IGBT based microprocessor controlled power generation unit for the ceramic electrodes
Chiller Specifications
Liquid Chiller System 600 Kcal/Hr capacity to maintain a temperature of 19°C to 22°C for the electrode
Compressor Emersion Copeland hermetically sealed with automatic Over load protection
Condenser Air cooled with Nippon copper fin and tube type
Evaporator Fin and tube type heat exchanger SS 304 grade tank
Water pump CNP Nanfang inline Centrifugal Monobloc pump
Safety Features
AUTOMATION Fully automated control unit. High voltage (>245V AC) & lowVoltage (< 200 V AC)indication & cut offElectrode failure indication & cut off
CONSTRUCTION Rugged steel body for easy maintenance and solid strength
Electrical Specification
Input Voltage 230 V AC / 50HZ (single phase)
Power consumption 2.2 Kilo Watts
Dimensions 730mm (W) 680mm (D) X 800mm (H)