Contact Us

MODEL NO: TZ 100AW Download Brochures


TZ 100AW
Characteristics

  • High Concentration
  • Less Foot Print
  • Fully Automated PLC Control
  • Timing, Sleeping, Auto and other multiple intelligence mode
  • Stylish
  • Integrated

 

Feed Gas preparation
Sl Particulars Specification
1.1 Feed Gas Inbuilt Oxygen concentrator
1.2 Type of oxygen generator The PSA model with 2 molecular Oxygen Sieve bed
1.3 Outlet Pressure 14 psi (1 bar)
1.4 Compressor Air flow oil less
1.5 Oxygen Purity 93% ± 3%
1.6 Oxygen flow control 1 to 16 LPM
1.7 Sound Level <= 45 dB (A)
1.8 Power supply AC 230V+ 10%, 50 Hz + 10%
1.9 Electrical classification II class B type
1.10 Temperature range 10° C – 45° C
1.11 Relative Humidity 20% to 70%

 

CONTROL PANEL

 

 

Sl FEATURES ADVANTAGES
2.1 Make Delta
2.2 PLC Slim Standard Type PLC
2.3 Standard mode bus ASCII / RTU / Protocol
2.4 Class of Insulation IP 20
2.5 Text Display HMI, High Color & wide Screen
2.6 Support USB client for High Speed Upload / Download

 

OZONE GENERATION
3.1 OZONE OUTPUT 100 GRMS PER HOUR
3.2 OZONE CONCENTRATION 100GM / CUM
3.3 Make & Type of Electrode Technozone make / Alumina coated ceramic tube electrode with high concentration of ozone
3.4 Cooling tube arrangement / material of the tube Water cooled SS 316 inner & 304 outer cooling water jacket tube. Flange ended with Teflon (zero leak proof). Can withstand pressure up to 4 bar
3.5 No. of electrodes Two
3.6 Ozone Generation by Corona discharge technology Advanced Ceramic coated & glazed electrode covered with concentric annular SS cooling tube is alternated with high frequency corona discharge. This corona discharge disassociates the oxygen atoms to regroup to form ozone
3.7 Power electronics Full bridge IGBT based microprocessor controlled power generation unit for the ceramic electrodes. Quantity: 1nos
3.8 CONTROLS Program Logic Control and Microprocessor, Based Control With Touch Screen Display
3.9 FEED BACK SYSTEM Auto Control Off for a) Gas Input b) Cooling Water Input c) High Current Failure d) High Temperature e) Electrode Failure

 

CHILLER SPECIFICATION
4.1 Liquid Chiller System 1000Kcal/Hr capacity to maintain a temperature of 19°C to 22°C for the electrode
4.2 Compressor Emersion Copeland, hermetically sealed with automatic overload protection
4.3 Condenser Air cooled with Nippon copper fin and tube type
4.4 Evaporator Fin and tube type heat exchanger SS 304 grade tank
4.5 Water pump CNP Nanfang inline Centrifugal Monobloc pump

 

SAFETY FEATURES
5.1 AUTOMATION Fully automated control unit & 100% leak proof. High voltage (>245VAC) & low voltage (< 200 V AC) indication & cut off Chiller low flow cut off Electrode failure indication & cut off
5.2 CONSTRUCTION Rugged steel body for easy maintenance and solid strength

 

ELECTRICAL SPECIFICATION
6.1 Input Voltage 230 V AC (single phase)
6.2 Frequency 50 Hz
6.3 Power consumption 3 Kilo Watts including Chiller, oxygen concentrator

 

DIMENSION
7.1 1050 mm width X 500 mm depth X 1425 mm height

 

TECHNICAL DETAILS
9.1 Operating Principle Voltage Source Inverter with PWM Control Technique
3rd Generation IGBT’s are used in the inverter
9.2 The Mode of Operation V / F Control
9.3 Type of Inverter The is Microprocessor control based digital Inverter
9.4 AC input Supply Single Phase 230 V / 50 HZ
9.5 Sensing Resolution 10bit voltage sensing Resolution
10 bit current sensing Resolution
10 bit High voltage Regulation
9.6 Desired Performance Switching Duty
9.7 Operating Parameters Automatic Soft start control
Input power monitoring
Adjustable current Limit
Closed loop HV regulation
9.8 Protection Over Current
High Voltage
Low Voltage
High Temperature
Low Pressure Control
Low Flow control
Power Good Failure